Description
| Model | SUN-7K-SG05LP1-EU-SM2 | SUN-7.6K-SG05LP1-EU | SUN-8K-SG05LP1-EU-SM2 | SUN-10K-SG05LP1-EU-SM2 |
| Battery Input Data | ||||
| Battery Type | Lead-acid or Lithium-ion | |||
| Battery Voltage Range(V) | 40-60 | |||
| Max.Charging Current(A) | 175 | 190 | 190 | 210 |
| Max.Discharging Current(A) | 175 | 190 | 190 | 210 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | |||
| Number of battery input | 1 | |||
| PV String Input Data | ||||
|
Max. PV Access Power (W)
|
14000 | 15200 | 16000 | 20000 |
| Max PV Input Power(W) | 11200 | 12160 | 12800 | 16000 |
| Max PV Input Voltage(V) | 500 | |||
| Start-up Voltage(V) | 125 | |||
| MPPT Voltage Range(V) | 150-425 | |||
| Rated PV Input Voltage(V) | 370 | |||
| Max Operating PV Input Current(A) | 26+26 | |||
| Max Input Short-Circuit Current(A) | 34+34 | |||
| No.of MPP Trackers/No.of String Per MPP Tracker | 2/2+2 | |||
| AC Input/Output Data | ||||
| Rated AC Input/Output Active Power(W) | 7000 | 7600 | 8000 | 10000 |
| Max AC Input/Output Apparent Power (VA) | 7700 | 8360 | 8800 | 11000 |
| Rated AC Input/Output Current(A) | 31.9/30.5 | 34.5/33.1 | 36.4/34.8 | 45.5/43.5 |
| Max AC Input/Output Current(A) | 35/33.5 | 38/36.4 | 40/38.3 | 50/47.9 |
| Max Continuous AC Passthrough (grid to load)(A) | 50 | |||
| Peak Power (off-grid)(W) | 2 times of rated power,10s | |||
| Rated Input/Output Voltage/Range(V) | 220V/230 0.85Un-1.1Un | |||
| Grid Connection Form | L+N+PE | |||
| Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | |||
| Power Factor Adjustment Range | 0.8 leading-0.8lagging | |||
| Total Current Harmonic Distortion THDi |
<3% (of nominal power)
|
|||
| DC Injection Current | <0.5%ln | |||
| Efficiency | ||||
| Max Efficiency | 97.6% | |||
| Euro Efficiency | 96.5% | |||
| MPPT Efficiency | >99% | |||
| Equipment Protection | ||||
|
Integrated
|
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
|
|||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | |||
| Interface | ||||
| Communication Interface | RS485/RS232/CAN | |||
|
Monitor Mode
|
GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||
| General Data | ||||
| Operating Temperature Range |
-40 to +60℃, >45℃ Derating
|
|||
| Permissible Ambient Humidity | 0~100% | |||
| Permissible Altitude | 2000m | |||
| Noise | <45 | |||
| Ingress Protection(IP) Rating | IP 65 | |||
| Inverter Topology | Non-Isolated | |||
| Over Voltage Category | OVC II(DC),OVC III(AC) | |||
| Cabinet size(W*H*D)[mm] | 366×589.5×237 (Excluding Connectors and Brackets) | |||
| Weight[kg] | 26.8 | |||
| Warranty | 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
|||
| Type Of Cooling | Intelligent air cooling | |||
| Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | |||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||






Reviews